a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Measuring Tools

Fluke 726 Precision Multifunction Calibrators

Process calibration designed specifically for process industries



The Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals. It measures and sources almost all process parameters to calibrate almost anything. Use it to test sensors and valves, and to test and calibrate transmitters. The 726 interprets results without the help of a calculator and stores measurement data for later analysis.



Measurement capabilities



This precision multifunction calibrator measures volts, mA, pressure, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters. The 726 also sources and simulates volts, mA, thermocouples, RTDs, frequency to calibrate transmitters. Measures and/or sources pressure using when paired with any of the 50 Fluke 750P series Pressure Modules to test and calibrate pressure transmitters and other devices. The 726 can also:

- Source mA with simultaneous pressure measurement to conduct valve and I/P test

- Conduct enhanced flowmeter testing with frequency totalizer and frequency pulse train source mode



Designed for ease of use



The 726 has built-in features that make it easier to use in nearly any measurement situation. From its ability to store frequently used test setups, to programming custom RTD probe calibration constants for enhanced temperature measurement, or the integrated voltage input protection design that improves reliability, the 726 is built to perform. The use of two separate channels even allows you to measure, source, or view process signals simultaneously. The backlit display provides better visibility in low-light conditions, and the standard 3-year warranty provides extra confidence that the 726 will be there when you need it to be.



You can also use the 726 to:

- Capture the set, reset, and deadband of a pressure switch with the integrated switch test

- Calculate the transmitter error % to interpret calibration results without the use of a calculator

- Perform fast linearity tests with the auto-step and auto-ramp features

- Power a transmitter during test using 24 V loop supply and simultaneous mA measurement
Download
Produk Lainnya
9118A Thermocouple Calibration Furnace
Fluke 9118A Thermocouple Calibration Furnace
High performance furnace for thermocouple calibrations to 1200 °C

The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics. The 9118A is the most accurate, reliable, and flexible furnace in its class, meeting the demanding requirements of high-temperature thermocouple calibration.
714B Thermocouple Calibrator
Fluke 714B Thermocouple Calibrator
Key features
• Highly accurate, easy-to-use thermocouple temperature calibrator
• Measures and simulates 17 thermocouple types and millivolts
• Measures 4 to 20 mA signals while sourcing a temperature signal
• Comes with a magnetic hanger for convenient hands-free operation
• Features configurable source settings for quick linearity checks
VT08 Visual IR Termometer
Fluke VT08 Visual IR Termometer
The Fluke VT Series is built with legendary Fluke toughness and quality. With a compact design and enhanced functionality, temperature measurements are visualized, so you can obtain clear and accurate infrared thermal images.

9011 HighAccuracy DualWell Calibrator
Fluke 9011 High-Accuracy Dual-Well Calibrator
Widest temperature range available in a single dry-well
• Combined range from –30 °C to 670 °C, one unit – two blocks
• Two independent temperature controllers (hot and cold side)
• Stability to ±0.02 °C
• Multi-hole wells for calibrating up to eight probes simultaneously

To give you the widest temperature range available in a dry-well calibrator, we’ve combined two of our most popular units. The 9011 allows temperature probes to be calibrated from –30 °C to 670 °C in a single unit.