a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 3831-9170
/
628111042805
Measuring Tools

Fluke 6102, 7102, 7103 Micro-Bath Thermometer Calibrators

Portable and extremely stable
• World’s smallest portable calibration baths
• Calibrates sensors of any size or shape
• Stability to ±0.015 °C
• Ranges from –30 °C to 200 °C

Need portability and extreme stability? Fluke 6102, Fluke 7102, and Fluke 7103 Micro-Baths have both. We invented the Micro-Bath. And, while many have tried to duplicate it, none of them use proprietary Fluke Calibration controllers, so none of them deliver performance like a Fluke Calibration bath. Micro-Baths can be used anywhere for any type of sensor. The 6102 weighs less than 4.5 kg (10 lb.), with the fluid. It’s lighter and smaller than most dry-wells, has a spill-proof lid, and is easier to carry than your lunch. You can take it where you need to go without carts or excessive effort. Micro-Baths can even be transported with the fluid in them.
Download
Produk Lainnya
730G Digital Pressure Calibrator
Fluke 730G Digital Pressure Calibrator
Compact smart pressure solution for on site or field



The Fluke 730G Smart Digital Pressure Calibrator combines the performance of a precision test gauge with the power of a loop calibrator and includes internal HART communication capabilities. When used with a pressure test pump, the Fluke 730G makes a highly efficient and highly accurate calibrator that can test pressure gauges, pressure switches and pressure transmitters, making it ideal for workshop instruments, measuring laboratories and pressure laboratories.

- Built-in HART communication: The integrated HART communication functionality is easy to use and you can customize HART directly, with no additional adjustment tools needed.

- Precision Pressure and Current Measurement: The 730G series provides high precision 0.02% pressure measurement accuracy and 0.01% flow measurement accuracy to meet laboratory pressure setting requirements and achieve accurate pressure calibration results.

- Intuitive operation and ease of use: High-end LCD screen and dual jack design provide a more practical and efficient user experience.

- Paperless testing and reporting: The optional 730G/PCSW management software enables paperless testing giving you the ability to automatically generate test reports and document results.



Fluke 730G/PCSW Software

- Paperless pressure calibration management: Record calibration data, perform calibration tests automatically and generate calibration reports.

- Asset management: Easily manage proven equipment and pressure standards.

- Supported pressure devices include: analog pressure gauges, digital pressure gauges, pressure transmitters, pressure sensors and pressure switches.



Increase your pressure testing capabilities with the



Fluke-700PTPK Pneumatic test pump kit:

- Combine with Fluke-730G Series Gauge, 1000 psi (69 bar) or less

- Generates pressures up to 600 psi (40 bar) with the 700PTP-1 test pump

- Connect the 730G Series meter directly to the included PTP-1 hand pump

- Includes hoses and adapters to connect the device to the pressure device to be tested

- The hardened carrying case protects the pump and gauge and allows the gauge to remain connected to the pump



Fluke-700HTPK Hydraulic Test Pump Kit

- Combine with Fluke-730G Series Gauge, 1000 psi (69 bar) or higher

- Generates pressure up to 10000 psi (690 bar) with 700HTP-2 test pump

- Connect the 730G Series Meter directly to the HTP-2 hand pump

- Includes a 700HTH-1 hose and adapter for connecting to the pressure device to be tested.

- The hardened carrying case protects the pump and gauge and allows the gauge to remain connected to the pump
Fluke Calibration 6531 6532 EDWT Electronic Deadweight Tester Kits
Fluke Fluke Calibration 6531, 6532 E-DWT Electronic Deadweight Tester Kits
Fluke Calibration electronic deadweight tester kits feature E-DWT-H configurations combined with the accessories needed for a complete calibration system. Model 6531 options feature E-DWT-H configurations with a single quartz reference pressure transducer (Q-RPT) to offer percent of reading performance from 10 % to 100 % of device full scale. Model 6532 options feature an additional Q-RPT to maximize workload coverage, with percent of reading performance from 1 % to 100 % of device full scale. An included vacuum fill kit allows the E-DWT to be filled with your choice of compatible fluid, while eliminating problematic air pockets from the test circuit. Also included is a test station adapter to mount just about any pressure device to be tested without using PTFE tape or wrenches. 6531 and 6532 kits provide all you need to perform high level hydraulic pressure calibration right out of the box.
• Pressure ranges available to 200 MPa (30,000 psi)
• ± 0.02 % of reading total one-year accuracy, 0.025 % for two years
• Low torque variable volume allows for pressure generation and control up to 200 MPa (30,000 psi) with minimal physical effort
• Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation
• Unique test port design eliminates the need for PTFE tape or wrenches. Adapters included for 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5
• Compatible with a wide range of liquids, including water. Vacuum fill kit included to fill the E-DWT with any compatible test medium
• AutoTest™, AutoRange, ready/not ready indicator, onboard data capture and storage, overpressure alarm, RS-232 remote interface and other advanced features to simplify testing, improve safety and prevent calibration errors and damage to equipment
• Optional foot switch accessory allows hands-free data collection when running AutoTests
• Rechargeable battery pack and transport case options for field operation

Key Features
• Eliminates the need for weights and piston-cylinder changes.
• Real-time pressure indication without need for corrections.
• Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
• Offers ± 0.02% of reading total one-year measurement uncertainty.
9132 and 9133 Portable Infrared Calibrators
Fluke 9132 and 9133 Portable Infrared Calibrators
Precision when you need it for infrared temperature calibration

Fluke 9132 and Fluke 9133 Portable Infrared Calibrators features:
• Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
• Large 57 mm (2.25 in) blackbody target
• RTD reference well for contact temperature measurement
• Small, compact design in a blackbody calibrator

Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30 °C to 500 °C.

These blackbody calibrator units feature a temperature controlled measurement surface with a diameter of 2.25 in (57 mm). The target temperature can be controlled in set-point increments of 0.1° from –30 °C to 500 °C and a well is located directly behind the blackbody surface for contact temperature measurement.
Euro Tester  150mm
Kennedy Euro Tester - 150mm