New testing process on control valves
The valves are opened and closed proportionally, and the degree of movement is varied depending on a signal varying between 4 - 20 mA applied to the input. Many valves have a feedback signal that shows the actual position as a percentage open/close value. This output can be a 4 - 20 mA signal or a digital HART variable that represents a 0 - 100 percentage of the control valve operating range.

Another important indicator of valve performance is the pressure required by the valve to move to the desired position. For example, a valve can be programmed to know if a 12 mA signal is applied it can open 50%. Smart electronics will control whether a smart pressure regulator is needed to increase or decrease the pressure when needed to move the control element to the desired position.

Providing a varying mA signal while monitoring the output milliamps or percentage of the trip signal will tell you whether a control valve is operating properly over its working range. Similarly, monitoring and recording the pressure applied to the final control elements while varying the 4 - 20 mA input signal to the valves is an important test to identify whether a valve is stuck. The relationship between pressure and mA or valve position will usually be linear if the valve is operating properly. If additional pressure is required it can often be considered for a stuck valve and will be shown if the measurement is recorded and plotted on a graph. By recording these signals, valve performance can be documented. These documented tests and results are usually called valve “characteristics”.

The valve usually includes a simple manual indicator that gives you an estimate of the percentage of movement to determine when it is operational. However, this indicator does not show you how the valve will operate under dynamic and changing conditions, and its accuracy is not guaranteed.
READ MORE
Event Con-Mine 2023
Many visitors came to Fluke's booth during the Event Construction, Infrastructure & Mining Solution (CON-MINE 2023), Thursday (1/1/2023). The exhibition, which lasted for a week at the Jakarta International Expo (JIExpo) Kemayoran Jakarta with the theme Sustainable Solutions for the Manufacturing Industry, included exhibitions on machinery, equipment, materials and services involving more than 500 exhibitors from all over Indonesia. .

alt text
The Marketing Division of PT Narmada Setia Indonesia took a group photo at the Event Construction, Infrastructure & Mining Solution (CON-MINE 2023) Jakarta International Expo (JIExpo) Kemayoran Jakarta.
READ MORE
How air leak detection equipment
Fluke interviews a factory regarding an air leak. These manufacturers really help keep the wheels of the trade moving. As one of the world's leading aftermarket manufacturers of wheel service equipment, the company designs, builds and markets products with whom they are trusted and recognized.

Many of the manufacturer's processes rely on compressed air to run the approximately 400 devices in the 13,935 square meter plant—all from 200 horsepower compressors. “We use compressed air everywhere in the plant—for pneumatic tools, robot welding, laser cutting, and powder paint equipment,” says the manufacturer's president. From the compressed air comes noise and—air leakage.

Controlling energy waste

Air leaks cause compressed air driven equipment to work harder, causing wasted energy. The possibility of air leaks in the plant increases with the presence of old equipment accumulated over the last decades from various plant consolidations. Listening for air leaks can be very difficult in noisy environments, so most leak detection activities are performed after business hours.

“Usually we wait until the building gets very quiet—a shift change or maintenance shutdown and we just try to listen for air leaks as much as we can,” says the maintenance supervisor. "We also use bottles of soapy water to spray any areas where there may be leaks and look for bubbles." The spray and see method requires that the maintenance team member is close enough to a possible leak to hear it and spray the solution in the correct area.

Another method for finding compressed air leaks is using an ultrasonic leak detector. This method requires highly trained personnel and a considerable amount of time is required to find all leaks. Small leaks can be hard for the human ear to hear, and not all leaks are in easily accessible areas. This can be a troublesome task.
READ MORE
Kamera Pencitraan Termal untuk Inspeksi Bangunan dan Rumah
Thermal Imaging
Jika kebocoran panas melalui sistem HVAC tidak terdeteksi dan ditangani, konsumsi energi akan makin boros. Biaya yang ditanggung oleh pemilik rumah dan bisnis pun makin membengkak. Beberapa tahun lalu, Chip Wade, kontraktor profesional menjelaskan satu kiat kepada kami. Ia mengatakan bahwa memeriksa sistem HVAC dengan teknologi pencitraan termal merupakan cara terbaik dan tercepat untuk menunjukkan sumber kebocoran energi HVAC kepada pemilik rumah dan bisnis.

Ada beberapa hal tidak pernah berubah.

Sejak dipublikasikannya video dari Chip, inovasi dalam teknologi pencitraan termal kini mampu menghasilkan citra dan video yang lebih detail. Dalam beberapa kasus pun, inovasi tersebut mampu mendeteksi imbas masalahnya.

Tonton video Chip yang mengajak kita menjelajahi rumah berusia 100 tahun untuk memahami penggunaan pencitraan termal guna mengidentifikasi kebocoran panas secara cepat dan efisien melalui sistem HVAC.



Transkrip:

“Saat melakukan pemeriksaan rumah yang akan dijual atau direnovasi, efisiensi energi adalah salah satu hal yang perlu Anda pertimbangkan. Sudah barang tentu, inilah yang berkutat di benak sang pembayar tagihan energi.

Fluke TiR1 thermal imager adalah alat terbaik untuk memeriksa kebocoran panas di saluran pipa, dinding, dan sekitar ventilasi. Seperti yang kita duga, ada beberapa area di rumah berusia ratusan tahun ini yang perlu diperbaiki.

Pertama, ventilasi. Idealnya, saat menutup ventilasi, Anda tidak ingin ada udara panas keluar dari situ. Coba lihat ventilasi tertutup ini melalui Fluke TiR1. Ventilasi tua ini tidak tertutup rapat sehingga ada kebocoran energi.

Sekarang kita berada di kamar mandi lantai atas. Di sini ada masalah yang sudah menyebar di saluran pipa rumah ini. Jika Anda melihat ventilasi tertutup ini melalui pencitra, tampak panas keluar dari keempat sisinya. Jika melihat di sebelah kanan, panas akan keluar dari atas dan bawah baseboard. Artinya, ada kerusakan sambungan pipa dan insulasinya sangat minim. Ini, kebocoran energi ini bisa membuat tagihan pemilik rumah membengkak.

Mari kita menuju ke basement untuk melihat kondisi saluran pipa.

Nah, kita sudah di basement. Dengan mendongak, bisa dilihat bahwa tidak ada insulasi di saluran pipa ini. Menggunakan Fluke TiR1, Anda bisa melihat dan menjelaskan semuanya kepada klien. Cukup lihat warna oranye cerah itu.

Pemilik rumah ini terus memanaskan suhu basement tanpa sepengetahuannya. Artinya, ruang keluarga tidak mendapatkan panas yang dibutuhkan. Bagi pemilik rumah, ini adalah pemborosan.”
READ MORE