Fluke 1587 FC Insulation Multimeter

Keep yourself safe. Find hidden problems faster. Put the paperwork down.



Fluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.



Add diagnostics with Fluke Connect

The Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including:

- Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely.

- Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.

- Quickly find problems by saving and comparing measurements over time on a wireless device.

- PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster

- Memory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time

- Temperature compensation to establish accurate baselines and relevant historical comparisons

- Historical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)

- Provides memory storage through Fluke Connect Measurements to eliminate the need to write down results

- Includes live circuit detection to prevent insulation test if voltage >30 V is detected

- Supports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately)

- Incorporates VFD low-pass filter for accurate variable frequency motor drive measurements

- Includes auto-discharge of capacitive voltage for added user protection

- Measures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuity

- Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading

- Automatically powers off to save battery power

- Comes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.
Download
Produk Lainnya
9100S 9102S Handheld DryWells
Fluke 9100S, 9102S Handheld Dry-Wells
World’s smallest, lightest and most portable dry-wells
• Smallest dry-wells in the world
• Ranges from –10°C to 375°C
• Accuracy to ±0.25°C, stability of ±0.05°C at 0°C
• RS-232 interface

Fluke Calibration's line of portable dry-wells is incredible. They’re the smallest, lightest, and most portable dry-wells in the world. And now they're better than ever!
393 Solar Clamp Meter CAT III 1500 V
Fluke 393 Solar Clamp Meter CAT III 1500 V
The Fluke 393 FC CAT III 1500 V True-rms Solar Clamp Meter with iFlex is designed for solar photovoltaic (PV) installation technicians and maintenance professionals who work in high voltage DC environments: PV arrays, wind power, electric railways, data centers battery banks for uninterruptible power supplies. The clamp meter will measure up to 1500 V DC and 1000 V AC with test leads, and up to 999.9 A DC or AC through the clamp jaw. The included iFlex flexible current probe extends AC current measurements up to 2500 A. The 393 has a thin jaw, giving you access to cables in crowded combiner boxes. Plus, the test leads are designed with your work in mind, and are also rated to CAT III 1500 V DC.



Key functions of the solar clamp meter:

- IP54 rated, ideal for work outdoors including PV panel testing

- DC power measurement, showing readings in kVA

- Audio Polarity indicator helps prevent accidental miswires

- Visual Continuity provides a bright green light in the display, ideal when working in dark and noisy environments

- Logging and reporting of test results via Fluke Connect software

- When measuring ac current the included iFlex flexible current probe gives you unparalleled access to cable is tight spaces. The iFlex probe can be twisted through extremely small spaces and provide accurate current measurements.



The world's first CAT III 1500 V true-RMS solar clamp meter
Fluke Calibration 700HPPK Pneumatic Test Pump Kit
Fluke Fluke Calibration 700HPPK Pneumatic Test Pump Kit
The Fluke Calibration 700HPPK Pneumatic Test Pump Kit generates and adjusts pneumatic pressures up to 21 MPa (3000 psi), without requiring a nitrogen bottle or other external pressure supply. It supplies pressure to devices under test (DUTs) that include transmitters, controllers, pilots, digital and analog gauges, and more. It’s the perfect solution for generating high pressure in the field, where conditions and operating surfaces can vary.
The 700HPPK is the ideal choice for calibration technicians, test engineers, and instrument technicians working in industries like natural gas transmission and distribution, process, aerospace and defense, who need a simple-to-use, safe and portable pressure source that they can depend on in a wide variety of conditions.
The 700HPPK contains both a calibration manifold and high pressure pump to generate and finely adjust pressures. A second model, the 700HPP, is available for people who only prefer a high pressure source.
Use the 700HPPK Test Pump Kits with 2700G Reference Pressure Gauges or 700G Precision Pressure Gauges for a complete pressure calibration solution.
Use the 700HPPK just about anywhere
The 700HPPK is designed to be at home in the lab or the field. Lightweight and portable, it features collapsible feet, built-in handhold, and a canvas carrying case, making it easy to carry to the field.
The 700HPPK works on just about any surface, so you don’t need a flat laboratory bench or flat area in the field.
With the 700HPPK, you don’t need to carry a lot of extra equipment or accessories. No PTFE tape or extra tools are required thanks to a swivel ¼ NPT female reference gauge connector that makes switching reference gauges fast and easy.
The pump kit is designed so that the calibration manifold attaches and detaches easily via quick detent pins. You won’t need to spend a lot of time setting it up or packing it away at the end of the day.
Generate high pressure accurately and safely for a wide workload
The 700HPPK generates pressure up to 21 MPA (3000 psi) within 20 seconds to full scale into a 10 cm3 volume. A detachable pressure adjustment system and adjustment control knob enables users to make fine pressure adjustments to 0.1% of reading or better. The 700HPPK includes a 2 meter (6.5-foot) pressure line and assorted pressure fittings, enabling you to connect a wide variety of DUTs for wide workload coverage. In fact, the 700HPPK covers at least five times more workload than standard range pneumatic pumps. An in-line filter system protects the system against contamination from the unit under test.

Key Features
• Generate and adjust pneumatic pressures up to 21 MPa (3000 psi)
• Rugged, portable and stable enough to go anywhere -- on any surface
• Reaches pressure in 20 seconds to full scale into a 10 cm3 volume
• Detachable pressure adjustment system for adjusting pressure, connecting reference and test devices on bench and in the field, and isolating and venting pressure
• Easily switch out reference gauges without requiring PTFE tape or tools
• 2-meter (6.5-foot) pressure line and assorted pressure fittings enable a wide variety of possible connections
• In-line filter and desiccant systems protect device from contamination from the DUT

Fluke Calibration P3200 Hydraulic Deadweight Tester
Fluke Fluke Calibration P3200 Hydraulic Deadweight Tester
The P3200 models are available in single or dual piston formats for increased operating ranges. Units can be supplied in psi, bar, kgf/cm², and MPa. This robust instrument is highly accurate, quick and easy to use. Units feature a built-in priming pump for large volume applications, piston flotation indicators and a high quality screw press for fine pressure control.
Options
PressCal software for pressure calculations and certificate generation
Operating principle
Deadweight testers are the high performance pressure standard for pressure measurement. Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated weight masses (Force) are loaded on the piston (Area), which rises freely within its cylinder. These weights balance the upward force created by the pressure within the system. The pressure is measured when placed on a correctly spinning and floating piston. The total pressure measured is the summation of the weights plus the piston weight carrier assembly.
Instrument base
There are three basic variations in the hydraulic offering; single low pressure, single high pressure and dual piston models. Pressure is generated and controlled by means of a high quality screw press located on the front of the tester. A built-in hand pump is included as standard for all hydraulic models to prime the system and accommodate large volume requirements.

Piston/cylinder assemblies

The piston/cylinder assembly is the heart of each deadweight tester. They are manufactured from materials that provide stability, durability, and low thermal coefficients and distortion. Our experience and knowledge of piston/cylinder production and calibration ensure the precision and performance required for today’s demanding calibration requirements.

Weight masses

Standard weight masses are series 3 nonmagnetic austenitic stainless steel. Each mass is marked with the serial number of the instrument and the nominal pressure value relative to the high or low-pressure piston, when applicable. Optional fractional weights are stainless steel and/or solution heat treated aluminum.
Gravity correction

Gravity varies significantly with geographical location and this variation has a direct effect on the force of the weights and the accuracy of the deadweight tester. Each instrument can be calibrated to local gravity at no extra cost. If unspecified, instruments will be calibrated to Standard Gravity at 980.665 cm/s2.

Key features
• Pressure ranges to 10,000 psi (700 bar)
• 0.015% of reading accuracy standard (0.008% optional)
• Single or dual piston formats
• Built-in hand pumps standard
• Mounted spirit level with adjustable feet
• Units can be trimmed to local gravity FOC