Schneider Masterpact NT external power supply module, input voltage 200 V AC to 240 V AC 50/60 Hz, output voltage 24 V DC, output current 1 A

ComPacT circuit breakers feature Schneider Electric’s exclusive Roto-Active Breaking System; it reduces the effects of short circuits of your installation. Today, the ComPacT range is optimized with a high level of breaking capacities, outstanding selectivity and cascading. It offers more advanced functions and ergonomic designs for easy installation and operations.
Download
Produk Lainnya
Lantern LED Rechargeable 90lm 75m Beam Distance
Edison Lantern, LED, Rechargeable, 90lm, 75m Beam Distance
Features one watt LED light and side LED tube light, two position handle. 5V 4Ah sealed lead acid battery. Supplied with AC/DC mains charger and 12V DC car plug adaptor.

Features and Benefits
• 2 million candle power, super bright 1W front LED light, side LED tube light and two position handle
• Impressive beam distance of up to 75m
• Run time of up to 6 hoyrs from the main beam mode, 30 hours from the side beam
• Supplied with main charger and in-car charger

ACB 1000A 3P 100kA
Siemens ACB 1000A 3P 100kA
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.
Miniature circuit breaker Domae 2P 2 A C Curve 6000 A
Schneider Miniature circuit breaker, Domae, 2P, 2 A, C Curve, 6000 A
This Domae product is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 1 protected poles and 2A In rated current and C tripping curve. The Icn rated short circuit breaking capacity is up to 6000A at 230VAC conforming to EN/IEC 60898-1 standard. It is compliant with IEC 60898-1 standard. This miniature circuit breaker protects circuit against short circuit and overload current. Mechanical durability goes up to 20000 cycles and electrical durability goes up to 10000 cycles. The Ue operational voltage is going from 230VAC. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 4 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 81mm x (D) 71.5mm. The weight is 0.190kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -5°C to 60°C. The storage temperature is -40°C to 85°C.
M12 LED Spotlight
Milwaukee M12™ LED Spotlight
M12 SLED-0
• Up to 640M Beam Distance
• 3 Light Output Modes for Distance, Clarity, and Safety
• High Mode: 750 lumens for up to 4 hours with M12™ 4.0Ah Pack