124B Industrial ScopeMeter HandHeld Oscilloscope 40 MHz
Fluke 124B Industrial ScopeMeter Hand-Held Oscilloscope, 40 MHz
Fluke 124B Offers



Compact and rugged, this oscilloscope is ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. Features innovative functions that help technicians troubleshoot faster for quicker results and to keep their systems running smoothly. Additionally, triggering displays waveforms without having to adjust amplitude, timebase, and trigger settings.



Features

- Key measurements: Voltage and power waveforms

- Automatically capture, view and analyze complex waveforms: Fluke Connect and View™ triggering automatically displays waveforms without having to adjust amplitude, timebase and trigger settings, while Intellaset™ technology analyzes the signal and automatically displays critical numerical readings, making troubleshooting faster than ever

- View data locally on the instrument, or via Fluke Connect mobile app

- Dual-input digital oscilloscope and multimeter

- 40 MHz oscilloscope bandwidth

- Two 5000-count true-rms digital multimeters

- Connect-and-View trigger simplicity for hands-off operation

- IntellaSet technology automatically and intelligently adjusts numerical readout based on the measured signal

- Dual-input waveform and meter reading recorder for trending data over extended periods

- Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz

- Shielded test leads for oscilloscope, resistance and continuity measurements

- Resistance, continuity, diode and capacitance meter measurements

- Power measurements (W, VA, VAR, PF, DPF, Hz)

- Save or recall data and instrument setups

- Store instrument setups defined by a test sequence for routine maintenance or most often used test procedures

- External optically isolated USB interface to transfer, archive and analyze scope or meter data

- Optional WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect mobile app

- Rugged design to withstand 3 g Vibration, 30 g shock, and rated IP51 according to EN/IEC60529

- Highest safety rating in the industry: safety rated for CAT IV 600 V



Connect-and-View triggering for an instant, stable display



Oscilloscope users know how difficult triggering can be. Using the wrong settings can lead to unstable waveform captures, and sometimes the wrong measurement data. This instrument's unique Connect-andView triggering technology recognizes signal patterns and automatically sets up the correct triggering to provide a stable, reliable, and repeatable display. Connect-and-View triggering is designed to work with virtually any signal, including motor drives and control signals - without adjusting parameters, or even touching a button. Signal changes are instantly recognized and settings are automatically adjusted, providing a stable display even when measuring multiple test points in quick succession.



IntellaSet/AutoReading



The Auto Readings function with Fluke IntellaSet technology uses proprietary algorithms to intelligently analyze the measured waveform and automatically displays the most appropriate numerical measurements on the screen, so you can get the data you need easier than ever before. As an example, when the measured waveform is a line voltage signal, the Vrms and Hz readings are automatically displayed, whereas if the measured waveform is a square wave, the Vpeak-peak, and Hz readings are automatically displayed. Using IntellaSet technology in conjunction with Connect-and-View automatic triggering you can be sure you're seeing not only the correct waveform but the appropriate numerical reading as well. All without touching a button.



Industrial equipment needs a reliable power supply to operate properly, use the dual input to obtain key power measurements



For single-phase or 3-phase balanced systems, the dual inputs of the Industrial ScopeMeter 120B Series can measure AC+DC RMS voltage on channel A and AC+DC RMS current on channel B. This oscilloscope can then calculate; frequency, phase angle, active power (kW), reactive power (VA or var), power factor (PF), or displacement power factor (DPF) and can also calculate the power values for a 3-phase system where all phases have equal voltage and currents. This applies to both balanced systems and resistive loads.



One test lead to measure multiple electrical parameters



High-frequency waveform, meter, capacitance, and resistance measurements as well as continuity checks are all covered by a single set of shielded test leads. No time is wasted finding or swapping leads.



Fluke Connect mobile app compatibility



Automated industrial machinery is harder than ever to troubleshoot. It's not enough to just know where you have to test, you also have to know what to look for and that can be hard without baseline measurement data or access to subject matter experts. This Fluke Connect Assets wireless system of software and wireless test tools enables technicians to reduce maintenance costs and increase uptime with accurate equipment records and maintenance data that is easy to interpret, and share. Compare and contrast test point measurement data and trends so you can better understand signal characteristics and changes over time. And, by storing maintenance data on the Fluke Cloud you can enable team members to access it from wherever and whenever they need to so you can get advice or approvals in the field and get your systems up and running faster than ever before.



Use the comprehensive recorder modes to help find intermittent faults with ease



The toughest faults to find are those that happen only once in a while-intermittent event. They can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Other factors, like line outages and sags or the starting and stopping of a motor, can also cause intermittent events resulting in equipment shutdowns. When these events happen, you may not be around to see them. But, your Fluke ScopeMeter Test Tool will. You can either plot the minimum and maximum peak measurement values or record the waveform trace. And, with expandable micro SD memory, recording sessions can be done for up to 14 days. This recorder is even more powerful with the addition of Recorder Event Detect, which makes detecting and logging intermittent faults easier than ever. Just set a threshold on a meter reading or scope trace and deviations are tagged as unique events. You no longer need to search through masses of data to pinpoint faults, and can quickly step from one tagged event to the next, while still having access to the full data
125B Industrial ScopeMeter HandHeld Oscilloscope 40 MHz
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope, 40 MHz
The FLUKE 125B/INT is a 120B series ScopeMeter hand held oscilloscope with 40MHz bandwidth, 2 analogue channels and universal plug type. It is a rugged solution for industrial electrical and electro mechanical equipment troubleshooting and maintenance applications. This is a truly integrated test tool with oscilloscope, multimeter and high speed recorder in one easy to use instrument. It also integrates with Fluke Connect mobile app and FlukeView for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information. The 125B includes innovative functions designed to help technicians troubleshoot faster and it has rugged design to withstand 3g vibration and 30g shock. IntellaSet technology automatically and intelligently adjusts numerical readout based on measured signal. The oscilloscope is IP51 rated according to EN/IEC60529. It has 5.7inch colour active matrix TFT display (640 x 480 pixels) and qualified by 600V CAT IV, CE, CSA.

- Rise time of less than 8.75ns and input impedance of 1Mohm/20pF (without probes and test leads)

- Maximum sample rate of 400KSPS, optically isolated USB interface

- Meter and scope recorder, full function dual input scope and meter, scope cursor measurements

- Simplified testing, more insight and faster electromechanical troubleshooting

- Dual input digital oscilloscope and two 5000 count true RMS digital multimeters

- Bus health and power and harmonics measurements

- Recorder event detect captures elusive intermittent signals on repetitive waveforms up to 4KHz

- Voltage, current and power harmonics, power measurements (W, VA, VAR, PF, DPF, Hz)

- Dimension is 259mm x 132mm x 55mm (10.2inch x 5.2inch x 2.15inch) and weight is 1.4Kg

- Operating temperature range from 0°C to 40°C (battery operation) & 0°C to 50°C (power adapter)



Applications

Test & Measurement



Contents

Fluke 125B hand held oscilloscope, Shielded test leads with black ground leads, Black test lead (for grounding), Hook clips (red, blue), Banana to BNC adapters (black, x1), 10:1 voltage probe, i400s AC current clamp, USB angled adapter, Wi-Fi USB adapter, Switch mode power supply, Adapter/battery charger, Rechargeable Li-ion battery pack.



Footnotes

In addition, we have calibration services for this product. Choose from a Standard Certificated Service or an internationally recognised UKAS accredited calibration. Visit our calibration service page for more details.
1AC II NonContact Voltage Tester
Fluke 1AC II Non-Contact Voltage Tester
• Be aware of voltage easily - the tip glows red and a beeper sounds when voltage is detected

• Continuous self-test so you always know it’s working

• Voltage detection range for wide application use - 90 V to 1000 V AC or 200 V to 1000 V AC

• Audible/Silent mode for added convenience
52 II Dual Probe Digital Thermometer
Fluke 52 II Dual Probe Digital Thermometer

- Relative time clocks at MIN, MAX and AVG provide a time reference for important events

- The Electronic Offset function enables thermocouple error compensation to maximize overall accuracy

- Measures J, K, T, and E thermocouple types

- Result reading in ºC, ºF or Kelvin (K)

- Splash and dust resistant bag with shock absorbing holster

- Front panel that is easy to set up and operate

- Sleep mode increases battery life, typical 1000 hours of battery life

- The battery cover makes it easy to replace the battery without opening the calibration seal

- The optional ToolPak accessory allows the thermometer to be hung from any metal object (with a rare earth magnet) or secured around a pipe (with a - hook-and-loop strap) for hands-free operation.

- 3 year warranty
54 II B Data Logging Thermometer with Dual Input
Fluke 54 II B Data Logging Thermometer with Dual Input
The Fluke 50 Series II contact thermometer offers fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged hand test kit.
110 Truerms Digital Multimeter
Fluke 110 True-rms Digital Multimeter
Compact true-rms meter for accurate electrical installation and troubleshooting



The Fluke 110 is a versatile multimeter for electrical measurements and troubleshooting. Trusted by residential and commercial electricians for troubleshooting and maintenance. The Fluke 110 is intended for professional use where true-rms accuracy is required.



Key product capabilities

- True-rms ac voltage for accurate measurements on non-linear signals

- Great white LED backlight for working in dark areas

- Resistance and continuity

- Min./Max./Average to record signal fluctuations

- CAT III 600 V safety rating
117 Electricians Ideal Multimeter with NonContact Voltage
Fluke 117 Electrician's Ideal Multimeter with Non-Contact Voltage
Portable true-rms meter for commercial applications. The Fluke 117 is the ideal gauge for demand settings such as trade center buildings, hospitals, schools. The Fluke 117 includes integrated non-contact voltage detection to help get jobs done faster.



See also the Fluke 114 Electrical Multimeter, Fluke 115 Multimeter, and Fluke 116 HVAC Multimeter with Temperature and Microamp.
325 Truerms Clamp Meter
Fluke 325 True-rms Clamp Meter
Sturdy Flukes. Reliable Flukes. Flukes are accurate.



True-rms measurements and optimized ergonomics make the 320 Series Clamp Meters the best general troubleshooting tool for commercial and residential electricians. The 323, 324 and 325 series are designed to check for the presence of load current, AC voltage and continuity of circuits, switches, fuses and contacts. These small, sturdy clamp gauges are ideally suited for current measurements up to 400 A in tight cable enclosures. The Fluke 325 also offers DC current and frequency measurements.
355 True RMS 2000 A Clamp Meter
Fluke 355 True RMS 2000 A Clamp Meter
A versatile and rugged tool for high current applications



Confidently take reliable readings with true-rms, Fluke 355 and 353 digital clamp meters; the tool of choice for high current clamp-on amp meter sizes up to 2000 A. The extra wide jaws easily clamp around large conductors, which are typically found in high current applications. The extra robust design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when performing high power measures.



Accurate peak measurements are possible using the in-rush inrush mode, ideal for motor and inductive loads. The 355 also measures voltage and resistance, making it an ideal clamp meter for utility, electrical contractors and industrial service technicians.
369 Truerms Leakage Current Clamp Meter
Fluke 369 True-rms Leakage Current Clamp Meter
Reduced downtime - find current leaks without shutting down equipment



The Fluke 369 FC true-rms leakage current clamp meter helps users detect, document, record, and compare leakage current readings over time to prevent unexpected downtime, and identify intermittent trips of GFCI and RCDs, all without the need to turn the equipment off.



The Fluke 369 FC has a very large 61 mm clamp for working with extra large conductors. The clamps are fully coated so that they can accurately capture very small leakage signals, and can minimize external electromagnetic interference.



HD160C Heavy Duty TRMS Multimeter with Temperature
Fluke HD160C Heavy Duty TRMS Multimeter with Temperature
The Amprobe HD160C Heavy Duty Multimeter is designed for professional use in harsh environments. Its made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts.



Built with tough, fire-retardant thermoplastic that is resistant to grease and chemical spills and with shock-mounted components that are drop resistant to at least 8 feet, the Amprobe HD160C is unusually rugged and reliable. It has an extended voltage measurement capability of 1500 V DC and 1000 V AC, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients up to 12 kV, and it also measures temperature.
MDA550 Series III Motor Drive Analyzer
Fluke MDA-550 Series III Motor Drive Analyzer
Simplify complex motor drive troubleshooting with guided test setups and automatic drive measurement that provide reliable, repeatable test results.

The Fluke MDA 550 Motor-Drive Analyzer saves time and the hassle of setting up complex measurements, and simplifies the troubleshooting process. Simply select a step-by-step guided test and measurement will show you where to make voltage and current connections, while preset measurement profiles ensure you will get all the data you need for every critical motor drive part, from input to output, the DC bus, and the motor itself . Doing simple to complex measurements? MDA-550 can do it. What's more, making reports before (as-found) and after (as-left) repairs or adjustments becomes more practical. This is all thanks to its built-in report generator feature.



The MDA-550 is an ideal portable motor drive analysis testing tool. Not only that, this tool can also be used to safely detect and solve common problems in inverter-type motor drive systems.



- Measures main motor drive parameters , including voltage, current, DC bus voltage level and AC ripple, voltage and current unbalance and harmonics, voltage modulation, and motor shaft voltage discharge.

- Performs broader harmonic measurements to identify the impact of low and high order harmonics on your power system.

- Performs guided measurements of motor drive input, DC bus, drive output, motor input, and shaft measurements with step-by-step graphical diagrams of voltage and current connections.

- Uses simple measurement settings with preset measurement profiles to automatically trigger data collection based on the selected test procedure.

- Quickly and easily generate reports that are perfect for documenting problem solving and collaborative work with others.

- Measure additional electrical parameters with a complete 500 MHz oscilloscope, meter and logger capability for a wide range of electrical and electronic measurements in industrial systems



The Fluke MDA-550 Motor Drive Analyzer uses guided test measurements to make analysis even easier



Drive input



Quickly measure input voltage and current to see if values ??are within acceptable limits by comparing the rated voltage to the actual supply voltage. It then checks the input current to determine if the current is within its maximum rating and the conductor size is appropriate. You can also check if the harmonic distortion is within an acceptable level. There are two options for doing this: carefully examine the shape of the waveform or look at the harmonics spectrum screen which displays total harmonic distortion and individual harmonics.



Imbalance of voltage and current



Check the voltage unbalance at the input terminals so you can make sure the voltage unbalance is not too high (> 6-8%), and the phase rotation is correct. You can also check for current unbalance, as too large an imbalance can indicate a driving rectifier problem.



Wider harmonic measurement



Excess harmonics are not only a threat to your rotating machine, but also to other equipment connected to the mains power system. As well as being able to detect motor drive harmonics, the MDA-550 can also detect the potential impact of inverter switching electronics. The MDA-550 has three harmonic ranges, 1st to 51st harmonics, 1 to 9 kHz, and 9 kHz to 150 kHz providing the ability to detect harmonic pollution problems.



Bus DC



In motor drives, the conversion of AC to DC inside the drive is very important. The reason is that for the best drive performance it is necessary to have the right voltage and adequate smoothing with low ripple. High ripple voltages can be an indicator of a faulty capacitor or a faulty motor connected. The logging function can be used to dynamically check the performance of the DC bus in operating mode when load is applied.



Drive output



Check drive output focusing on voltage to frequency (V/F) ratio, and voltage modulation. If the V/F ratio is high, the motor may overheat. With a low V/F ratio, the connected motor may not be able to provide the torque required at the load to carry out the process for which it is intended.



Voltage modulation



Pulse Width Modulation signal measurements are used to check for high voltage peaks that can damage motor winding insulation. The rise time or steepness of the impulse is indicated by a dV/dt reading (value of change in voltage over time), this must be compared with the specified motor insulation. Metering can also be used to measure switching frequency. Its purpose is to detect whether there is a potential problem with the switching electronics, or with grounding, as the signal drifts up and down.



Input Motor



Ensuring the supply of voltage at the motor input terminal is important. However, choosing a connecting cable between the drive and the motor is no less important. Incorrect cable selection can cause damage to the drive and motor due to overvoltage peaks. Checking that the current at the terminals is within the motor's rating is critical because excess current can cause the motor to overheat, reducing the life of the stator insulation which can cause premature failure of the motor.



Motor shaft voltage



The voltage impulse in the variable speed drive is generated from the circuit between the motor stator and the rotor until a voltage appears on the rotor shaft. If the rotor shaft voltage exceeds the insulating capacity of the bearing grease, flashover currents (glow) may occur. As a result, pitting and fluting of the motor bearing rotation occurs, namely damage that causes the motor to fail prematurely. The MDA-550 is equipped with a carbon fiber brushed probe tip that makes it easy for you to detect destructive flashover currents. Meanwhile, the amplitude of the impulse and the number of events can be used as a consideration in taking preventive action. With the addition of these accessories and capabilities, you can spot potential faults without the need to buy expensive permanent solutions.



Step-by-step guided measurements ensure you have the data you need, when you need it



The MDA-550 is designed to help you quickly and easily test and troubleshoot common three-phase and single-phase inverter-type motor drive systems. Onscreen information and a step-by-step setup guide make it easy for you to configure the analyzer. Not only that, the information and guide will also provide the required drive measurements. That way, you can quickly make informed decisions regarding maintenance. From power input to attached motor, the MDA-550 provides measurement capabilities for the fastest motor drive solutions.