a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 3831-9170
/
628111042805
Measuring Tools

Fluke Fluke 500 Series Battery Analyzer

Reduced testing complexity, a simplified workflow and an intuitive user interface provide a new level of ease-of-use in battery testing.
• The ideal test tool for maintenance, troubleshooting and performance testing of individual stationary batteries and battery banks used in critical battery back-up applications
• The intuitive user interface, compact design and rugged construction ensure optimum performance, test results and reliability
• Covers a broad range of battery test functions ranging from DC voltage and resistance tests to full condition testing using automated string function testing and the test probe integrated infra-red temperature measurement system
• Designed for measurements on stationary batteries of all types.
Fluke BT510 key features:
• Battery Voltage – During the internal resistance test, Fluke Battery Analyzers also measure the voltage of the battery under test
• Discharge Volts – The Discharge mode collects the voltage of each battery multiple times at a user defined interval during a discharge or load test. Users can calculate the time a battery takes to drop to the cut-off voltage and use this time to determine the capacity loss of the battery
• Ripple Voltage Test – Measures unwanted residual ac component of the rectified voltage in dc charging and inverter circuits. Allows users to test ac components in dc charging circuits and find one of the root causes of battery deterioration
• Meter and Sequence Modes – The Meter mode is used for a quick test or troubleshooting. In this mode you can save and read the readings in a measurement or time sequence. The Sequence mode is for maintenance tasks with multiple power systems and battery strings. Before a task starts, users can configure a profile for the task for data management and report generation
• Threshold and Warning – Users can configure a maximum of 10 sets of thresholds and receive a Pass/ Warning/ Fail indication after each measurement
• Intercell Strap Resistance Test and Data Management – Measures the resistance of the intercell connection between batteries in a string.
• AutoHold – When AutoHold is turned on, a reading is captured when it remains stable for 1 second. The reading is then released when a new measurement starts
• AutoSave – When AutoSave is turned on, measured values are saved to internal memory automatically after an AutoHold reading is captured
• Fluke Battery Management Software – Easily import data from the Product to a PC. The measurement data and battery profile information is stored and archived with the Management Software and can be used for comparison and trend analysis. All measurement data, battery profile and analysis information can be used to easily generate reports
• Comprehensive logging – All measured values are automatically captured during testing and can be reviewed on the instrument before downloading for on the-go analysis
• Optimized user interface – Quick, guided setup ensures you're capturing the right data every time
• Battery life – 7.4 V 3000 mAh lithium-ion battery for more than eight hours continuous operation.
• USB port – For fast data download to supplied data analysis and report management application software.
• Highest safety rating in the industry – CAT III 600 V, 1000 V dc max. rated for safe measurements all around the battery power supply equipment.
Fluke BT520 Key features:
(Designed for measuring batteries in cabinets and hard to reach places)
• All of the above plus
• BTL20 Intelligent Test Probe set, with long and short probe extenders and built-in LCD display and speaker for visual and audio feedback
• BTL20ANG Intelligent Test Probe Set, with long and short angled tip probe extenders (no temperature sensor)
• Large soft carry case

Key Features
The ideal test tool for maintenance, troubleshooting and performance testing of individual stationary batteries and battery banks used in critical battery back-up applications
• Key measurements – Internal battery resistance, dc and ac voltage, dc and ac current, ripple voltage, frequency and temperature.
• Sequence measurement mode – Automatic or manual sequence testing of battery strings with automatic measurement storage including voltage, resistance and temperature (with BTL21 intelligent test probe), eliminating the need to press a button each time a measurement needs to be saved.
• Comprehensive logging – All measured values are automatically captured during testing and can be reviewed on the instrument before downloading for on the-go analysis.
Download
Products Lainnya
Fluke Calibration P3100 Hydraulic Deadweight Testers
Fluke Fluke Calibration P3100 Hydraulic Deadweight Testers
The P3100 models are available in single or dual piston format. Unit can be supplied in psi, bar, kgf/cm², and MPa. This robust instrument is highly accurate, quick and easy to use. Units feature a built-in priming pump for large volume applications, piston flotation indicators and a high quality screw press for fine pressure control.
Operating principle
Deadweight testers are the high performance pressure standards for pressure measurement. Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated weight masses (Force) are loaded on the piston (Area), which rises freely within its cylinder. These weights balance the upward force created by the pressure within the system. The pressure is measured when placed on a correctly spinning and floating piston. The total pressure measured is the summation of the weights plus the piston weight carrier assembly.
Instrument base
There are three basic variations in the hydraulic offering; single low pressure, single high pressure and dual piston models. Pressure is generated and controlled by means of a high quality screw press located on the front of the tester. A built-in hand pump is included as standard for all hydraulic models to prime the system and accommodate large volume requirements.
Piston/cylinder assemblies
The piston/cylinder assembly is the heart of each deadweight tester. They are manufactured from materials that provide stability, durability, and low thermal coefficients and distortion. Our experience and knowledge of piston/cylinder production and calibration ensure the precision and performance required for today’s demanding calibration requirements.
Weight masses
Standard weight masses are series 3 nonmagnetic austenitic stainless steel. Each mass is marked with the serial number of the instrument and the nominal pressure value relative to the high or low-pressure piston, when applicable. Optional fractional weights are stainless steel and/or solution heat treated aluminum.
Gravity correction
Gravity varies significantly with geographical location and this variation has a direct effect on the force of the weights and the accuracy of the deadweight tester. Each instrument can be calibrated to local gravity at no extra cost. If unspecified, instruments will be calibrated to Standard Gravity at 980.665 cm/s2.

Key features
• Pressure ranges to 60,000 psi (4000 bar)
• 0.015% of reading accuracy standard (0.008% optional)
• Single or dual piston format
• Built-in hand pumps standard
• Mounted spirit level with adjustable feet
• Units can be trimmed to local gravity FOC
568 Ex Intrinsically Safe Mini Infrared Thermometer
Fluke 568 Ex Intrinsically Safe Mini Infrared Thermometer
Use the Fluke 568 Ex for intrinsically safe temperature measurements anywhere in the world



The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is certified by major rating bodies for use in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex-rated areas around the globe. The simple, three-button on-screen menu interface is quick to use and makes even complex measurements easy. It takes just a few pushes of a button to adjust emissivity, record data, or turn on and off alarms. The 50:1 distance-to-spot ratio allows you to measure smaller objects from further away. And it also is compatible with K-type probes for contact measurements. Either way, you can count on the rugged, ergonomic design to stand up to tough conditions.



Other useful features:

- Instantly alerts you to measurements outside of set limits with audible and visual alarms

- Provides with 1% measurement accuracy

- Comes with thermocouple K bead probe and two-year warranty -30-

- Features a rugged, easy-to-use, ergonomic design that stands up to tough industrial, electrical, and mechanical environments

- Works with mini-connector K-type thermocouples

- Allows easy access to advanced features with soft-key buttons and graphical display

- Captures up to 99 points of data for quick downloading to a PC through the USB connection

- Powered by two AA batteries

- Allows you to confidently measure a wide variety of surfaces with adjustable emissivity and built-in materials table

- Easily adapts to lighting conditions with a two-level backlight
T61000 PRO Electrical Tester
Fluke T6-1000 PRO Electrical Tester
• Save time by seeing voltage and current measurements at the same time

• Visual Continuity™ – the screen automatically turns green for continuity, perfect when it’s too loud to hear the beeper

• FieldSense™ technology for ac voltage, current and frequency, all without making electrical contact to live voltage
369 Truerms Leakage Current Clamp Meter
Fluke 369 True-rms Leakage Current Clamp Meter
Reduced downtime - find current leaks without shutting down equipment



The Fluke 369 FC true-rms leakage current clamp meter helps users detect, document, record, and compare leakage current readings over time to prevent unexpected downtime, and identify intermittent trips of GFCI and RCDs, all without the need to turn the equipment off.



The Fluke 369 FC has a very large 61 mm clamp for working with extra large conductors. The clamps are fully coated so that they can accurately capture very small leakage signals, and can minimize external electromagnetic interference.