a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Measuring Tools

Kennedy 20 BLADE SCREW PITCH GAUGE 60 DEG METRIC

Ideal for accurately measuring internal and external thread forms. Manufactured from hardened and polished steel, the blades are precision milled for optimum accuracy. Enclosed in a steel case.



Featrures and Benefits

• Hardened and polished steel for increased durability

• With precision milled blades for accuracy

• Used to internal and external thread forms

• Enclosed in a steel case for easy storage and portability
Download
Products Lainnya
1760TR ThreePhase Power Quality Recorder
Fluke 1760TR Three-Phase Power Quality Recorder
The Fluke 1760 Three-Phase Power Quality Recorder complies strictly with IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent conformity testing. Designed for the analysis of utility and industrial power distribution systems, in medium and low voltage networks, these power quality monitors give customers the flexibility to customize threshold selection, algorithms and measurements. The Fluke 1760 power recorder records the most thorough detail for user-selected parameters.



Usage



Detailed fault analysis – Performs high-speed transient analysis and finds root causes of equipment malfunctions for later mitigation of malfunctions and predictive maintenance. The fast transient option, with a measuring range of 6,000 V, makes it possible to record very short impulses such as lightning strikes.



Class-A Quality of Service Compliance – Validates the quality of incoming power at the service gateway. Thanks to Class A conformance, the Fluke 1760 allows unquestioned verification.



Correlation of events at multiple locations – Using GPS time synchronization, users can quickly detect where a fault first occurred, both inside and outside the facility.



Galvanic separation and DC coupling – Allows complete measurement of dissimilar power systems. For example, troubleshooting a UPS system by simultaneously recording battery voltage and power output.



Power quality and power load monitoring – Assess baseline power quality to validate compatibility with critical systems prior to installation and verify electrical system capacity before increasing loads.
TiS55 Thermal Camera
Fluke TiS55+ Thermal Camera
Strong. reliable. Accurate At Fluke, we know accidents happen, tools that are dropped, kicked, stepped on, or bumped. You do not have to change the tool if it falls off the workbench or is splashed with water or dirt. That's why we designed the TiS55+ thermal camera to withstand drops from a height of 2 meters and is water/dust resistant (IP54). You need to know that your camera is ready to use at all times.

No need for a clipboard
With so many inspections in one day, it can be difficult to remember what you saw and where it was. Maybe you brought a clipboard with you to take notes. The TiS55+ comes with a built-in personal assistant, which means you can get rid of the clipboard and have all the information you need in the pictures you take, including:

- Voice notes
Records up to 60 seconds per thermal image
Identify exactly what you see in realtime
- IR-PhotoNotes
Take a photo of the asset number and other identifiers
Use as a reference when viewing thermal images on your computer
- Asset Tagging
Sort your images by assets
Scan the QR code on your asset and start taking thermal images
Connect your camera to your computer to view images, sorted by asset
9190A UltraCool Field Metrology Well
Fluke 9190A Ultra-Cool Field Metrology Well
Key features
Ultra-cool dry-block calibrator with best-in-class stability

The Fluke 9190A Ultra-Cool Field Metrology Well is the most accurate and stable, cold temperature dry-block on the market. It’s ideal for applications that demand strict quality control and regulatory process compliance. These applications include on-location validation and calibration of RTDs, thermocouples, thermometers, and sensors used with process control equipment such as medical freezers, laboratory refrigerators, cold rooms, blood banks, sterilizers (autoclaves), and freeze dryers.

Wide temperature range
–95 °C to 140 °C

Excellent accuracy
Accuracy using built-in referencethermometer readout: ±0.05 °C full range
Display accuracy: ±0.2 °C full range
Best-in-class stability
±0.015 °C full range

Fast cooling time
23 °C to –90 °C: 80 minutes
23 °C to –95 °C: 90 minutes
140 °C to 23 °C: 60 minutes

Portability
Weighs only 16 kg (35 lbs)
Built-in front and back handlesfor easy two-handed carry
Best measurement practices
Conforms with EURAMET cg-13 guidance on measurement practices for temperature calibrators
179 TrueRMS Digital Multimeter
Fluke 179 True-RMS Digital Multimeter
The three models of the new 170 Series are the new benchmark for common multimeters. All three set the standard with their combination of precision, features, ease of use, safety and reliability