a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Measuring Tools

Fluke 404E/406E/405/408/410 Laser Distance Meter

- Quickly measure distance, calculate area / volume / pythagoras

- Auto level and height

- Built to withstand rainy or dusty conditions: 1-meter drop tested with rated IP54 (Fluke 404E / 406E), IP65 (Fluke 405 / 408 / 410),

- Electronic angle display, auxiliary level measurement

- Up to 100 sets of data storage

- The battery life up to 5000 single measurements Automatically power off after 3 minutes of inactivity



Fluke 405 / 408 / 410 provide additional features as :

- Universal tripod interface, easy to use

- Type-C charging port, strong endurance

- 2-inch HD display, clear viewing in full sunlight
Download
Produk Lainnya
Fluke 1662 Multifunction Testers
Fluke Fluke 1662 Multifunction Testers
Fluke 1662 menawarkan keandalan Fluke, pengoperasian yang mudah, dan semua kemampuan pengujian yang diperlukan untuk pengujian instalasi sehari-hari.

Fitur utama
Fluke 1662 memberi lebih banyak daya di tangan Anda dengan menguji semua pengaturan lokal secara cepat dan efisien.
Fungsi pengukuran
• Fungsi pengukuran
• Tegangan & frekuensi
• Pemeriksa polaritas perkabelan, mendeteksi kerusakan kabel N
• Resistansi insulasi
• Kontinuitas & resistansi
• Pengukuran kumparan motor dengan pengujian kontinuitas
• Resistansi loop & line
• Prospective earth fault current (PEFC/IK)
• Prospective short-circuit current (PSC/IK)
• Waktu switching RCD
726 Precision Multifunction Calibrators
Fluke 726 Precision Multifunction Calibrators
Process calibration designed specifically for process industries



The Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals. It measures and sources almost all process parameters to calibrate almost anything. Use it to test sensors and valves, and to test and calibrate transmitters. The 726 interprets results without the help of a calculator and stores measurement data for later analysis.



Measurement capabilities



This precision multifunction calibrator measures volts, mA, pressure, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters. The 726 also sources and simulates volts, mA, thermocouples, RTDs, frequency to calibrate transmitters. Measures and/or sources pressure using when paired with any of the 50 Fluke 750P series Pressure Modules to test and calibrate pressure transmitters and other devices. The 726 can also:

- Source mA with simultaneous pressure measurement to conduct valve and I/P test

- Conduct enhanced flowmeter testing with frequency totalizer and frequency pulse train source mode



Designed for ease of use



The 726 has built-in features that make it easier to use in nearly any measurement situation. From its ability to store frequently used test setups, to programming custom RTD probe calibration constants for enhanced temperature measurement, or the integrated voltage input protection design that improves reliability, the 726 is built to perform. The use of two separate channels even allows you to measure, source, or view process signals simultaneously. The backlit display provides better visibility in low-light conditions, and the standard 3-year warranty provides extra confidence that the 726 will be there when you need it to be.



You can also use the 726 to:

- Capture the set, reset, and deadband of a pressure switch with the integrated switch test

- Calculate the transmitter error % to interpret calibration results without the use of a calculator

- Perform fast linearity tests with the auto-step and auto-ramp features

- Power a transmitter during test using 24 V loop supply and simultaneous mA measurement
9190A UltraCool Field Metrology Well
Fluke 9190A Ultra-Cool Field Metrology Well
Key features
Ultra-cool dry-block calibrator with best-in-class stability

The Fluke 9190A Ultra-Cool Field Metrology Well is the most accurate and stable, cold temperature dry-block on the market. It’s ideal for applications that demand strict quality control and regulatory process compliance. These applications include on-location validation and calibration of RTDs, thermocouples, thermometers, and sensors used with process control equipment such as medical freezers, laboratory refrigerators, cold rooms, blood banks, sterilizers (autoclaves), and freeze dryers.

Wide temperature range
–95 °C to 140 °C

Excellent accuracy
Accuracy using built-in referencethermometer readout: ±0.05 °C full range
Display accuracy: ±0.2 °C full range
Best-in-class stability
±0.015 °C full range

Fast cooling time
23 °C to –90 °C: 80 minutes
23 °C to –95 °C: 90 minutes
140 °C to 23 °C: 60 minutes

Portability
Weighs only 16 kg (35 lbs)
Built-in front and back handlesfor easy two-handed carry
Best measurement practices
Conforms with EURAMET cg-13 guidance on measurement practices for temperature calibrators
1760TR ThreePhase Power Quality Recorder
Fluke 1760TR Three-Phase Power Quality Recorder
The Fluke 1760 Three-Phase Power Quality Recorder complies strictly with IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent conformity testing. Designed for the analysis of utility and industrial power distribution systems, in medium and low voltage networks, these power quality monitors give customers the flexibility to customize threshold selection, algorithms and measurements. The Fluke 1760 power recorder records the most thorough detail for user-selected parameters.



Usage



Detailed fault analysis – Performs high-speed transient analysis and finds root causes of equipment malfunctions for later mitigation of malfunctions and predictive maintenance. The fast transient option, with a measuring range of 6,000 V, makes it possible to record very short impulses such as lightning strikes.



Class-A Quality of Service Compliance – Validates the quality of incoming power at the service gateway. Thanks to Class A conformance, the Fluke 1760 allows unquestioned verification.



Correlation of events at multiple locations – Using GPS time synchronization, users can quickly detect where a fault first occurred, both inside and outside the facility.



Galvanic separation and DC coupling – Allows complete measurement of dissimilar power systems. For example, troubleshooting a UPS system by simultaneously recording battery voltage and power output.



Power quality and power load monitoring – Assess baseline power quality to validate compatibility with critical systems prior to installation and verify electrical system capacity before increasing loads.