a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Measuring Tools

Kennedy 4" SPRING TYPE DIVIDERS-SOLID NUT

Manufactured from high quality polished steel. Ground finished points, a fine adjusting screw is mounted across the legs for setting the distance between the two points. A circular spring bow joins the legs, with a knurled extension attached for use when pivoting the dividers. Dividers are used for scribing arcs and circles, a light centre punch mark on the work keeps the pivot leg in the centre while marking.



Features and Benefits

• High quality polished steel with ground finished points

• Adjusting screw mounted across the legs for setting distance between points

• A light centre punch mark on the work keeps pivot leg in the centre while marking

• Ideal for use in scribing arcs and circle applications
Download
Produk Lainnya
9132 and 9133 Portable Infrared Calibrators
Fluke 9132 and 9133 Portable Infrared Calibrators
Precision when you need it for infrared temperature calibration

Fluke 9132 and Fluke 9133 Portable Infrared Calibrators features:
• Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
• Large 57 mm (2.25 in) blackbody target
• RTD reference well for contact temperature measurement
• Small, compact design in a blackbody calibrator

Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30 °C to 500 °C.

These blackbody calibrator units feature a temperature controlled measurement surface with a diameter of 2.25 in (57 mm). The target temperature can be controlled in set-point increments of 0.1° from –30 °C to 500 °C and a well is located directly behind the blackbody surface for contact temperature measurement.
T5600 Electrical Tester
Fluke T5-600 Electrical Tester
• Measure current up to 100 A without breaking the circuit

• Meter automatically selects AC or DC voltage, up to 600 V

• Resistance measurements up to 1000 Ω plus continuity test

• Work in tight spaces with detachable SlimReach™ probe tips
Fluke ii915 Acoustic Imager
Fluke Fluke ii915 Acoustic Imager
Fluke ii915 Acoustic Imager: Detect, Locate, and Assess Anomalies

The Fluke ii915 Acoustic Imager is a powerful tool designed to identify and evaluate issues in various systems. With three distinct modes—LeakQ™, PDQ™, and MecQ™—this innovative device empowers maintenance professionals to take proactive measures and prevent costly problems. Let’s explore its capabilities:

Leak Detection with More Sensitivity
LeakQ™ Mode: Detect Hidden Costs


Leaks in compressed air, gas, steam, and vacuum systems can lead to significant financial losses. The Fluke ii915 simplifies leak detection by allowing technicians to visualize sound. As they scan hoses, fittings, and connections, the built-in acoustic array captures decibel levels per frequency. The resulting SoundMap™ overlays on a visual image, making it easy to pinpoint leaks—even during peak operation hours. Say goodbye to time-consuming inspections and hello to efficient leak detection. Fluke ii915 has the high frequency range and best sensitivity to do acoustic leak detection more efficiently.

Early Mechanical Issue Identification
MecQ™ Mode: Efficient Inspection for Conveyor Systems


Conveyor systems are notorious for their complexity and potential to disrupt production. The Fluke ii915 acoustic camera revolutionizes inspection by enabling contactless scanning of large areas. Advanced noise filtering ensures clear images, even in high-noise environments. Detecting potential mechanical issues early allows targeted maintenance, preventing unplanned downtime. For seamless operation and proactive maintenance of large conveyance systems, the Fluke ii915 Acoustic Imager with MecQ™ is the ultimate choice.

Visualizing the Invisible Threat
PDQ™ Mode: Locating Partial Discharge


Partial discharge poses serious risks, from arc flash fires to blackouts. The Fluke ii915 translates partial discharge sounds into visuals, precisely pinpointing their location. With an extended frequency range of 2-100 kHz, this tool can detect partial discharge even earlier and aids maintenance planning to prevent catastrophic events. High-voltage electricians, electrical test engineers, and grid maintenance teams can now see what was once invisible.

Key features
• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQ™ Mode: Estimated leak size and cost.
• PDQ Mode™: Assesses discharge severity.
• MecQ™ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.
700G31 Pressure Gauge Calibrator 14 to 10000 psi
Fluke 700G31 Pressure Gauge Calibrator, -14 to 10,000 psi'
Fluke 700G31 Offers



Compatible with most hydraulic and pneumatic test pumps, users can also make use of Fluke's 700G/TRACK Software to upload over 8000 pressure measurements logged in the field.



Features

- Precision pressure measurement from ±10 inH2O to 10,000 psi (20 to 690 bar)

- Absolute pressure measurement ranges 15, 30, 100, 300 psia

- Accuracy to 0.05% of full scale

- Reference class gauge accuracies to 0.04% of reading

- Easy to use, rugged construction for reliable performance

- CSA; Class 1, Div 2, Groups A-D rating

- ATEX rating: II 3 G Ex nA IIB T6

- Combine with the 700PTPK or 700HTPK pump kits for a complete pressure testing solution for up to 600 psi (40 bar) with the PTP-1 pneumatic pump and up to - - 10,000 psi (690 bar) with the HTP-2 hydraulic pump

- Log up to 8493 pressure measurements to memory (requires 700G/TRACK software)