a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Measuring Tools

Fluke 566 Thermal Gun Infrared & Contact Thermometer

The 566 IR and contact thermometer features a simple, three-button, on-screen menu interface (in 6 languages) to make it easier than ever to measure temperature. You can quickly navigate advanced features to adjust emissivity, start data logging, or turn alarms on and off with just a few pushes of a button. And with its rugged, easy-to-use, ergonomic design, the Fluke 566 can stand up to tough industrial, electrical, and mechanical environments. These tools go beyond other IR thermometers (or pyrometers), helping you work more efficiently in more applications.



Other useful features:



- Adjustable emissivity that allows you to confidently measure a wide variety of surfaces

- Up to 20 points of data for downloading and recalling later

- Two levels of backlight on the display

- Included Type-K thermocouple bead probe

- Features audible and visual alarms to instantly alert you to measurements outside of your set limits

- Provides MAX, MIN, DIF and AVG functions to quickly identify problems
Download
Products Lainnya
Fluke 1503 Insulation Resistance Meter
Fluke Fluke 1503 Insulation Resistance Meter
The Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like the remote probe, reduce the time needed to perform repetitive testing.
Other useful capabilities:
• Measures AC/DC voltage from 0.1 V to 600 V
• Includes auto-discharge of capacitive voltage for added user protection
• Provides lo-ohms earth-bond continuity (200 mA)
• Simplifies repetitive or hard-to-reach testing with the remote test probe
• Saves battery power with auto power off
• Presents results on a large, backlit display
• Features CAT IV 600 V overvoltage category rating
• Comes with remote probe, test leads, test probes, alligator clips, and one-year warranty
• Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
• Runs on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests

Key Features
• A rugged, compact insulation resistance tester for residential and commercial electricians
• Performs insulation tests from 0.01 MΩ to 2000 MΩ
• Offers two insulation test voltages: 500 V and 1000 V
• Includes live circuit detection to prevent insulation test if voltage >30 V is detected
• Measures resistance from 0.01 Ω to 20.00 kΩ
Fluke Calibration 6531 6532 EDWT Electronic Deadweight Tester Kits
Fluke Fluke Calibration 6531, 6532 E-DWT Electronic Deadweight Tester Kits
Fluke Calibration electronic deadweight tester kits feature E-DWT-H configurations combined with the accessories needed for a complete calibration system. Model 6531 options feature E-DWT-H configurations with a single quartz reference pressure transducer (Q-RPT) to offer percent of reading performance from 10 % to 100 % of device full scale. Model 6532 options feature an additional Q-RPT to maximize workload coverage, with percent of reading performance from 1 % to 100 % of device full scale. An included vacuum fill kit allows the E-DWT to be filled with your choice of compatible fluid, while eliminating problematic air pockets from the test circuit. Also included is a test station adapter to mount just about any pressure device to be tested without using PTFE tape or wrenches. 6531 and 6532 kits provide all you need to perform high level hydraulic pressure calibration right out of the box.
• Pressure ranges available to 200 MPa (30,000 psi)
• ± 0.02 % of reading total one-year accuracy, 0.025 % for two years
• Low torque variable volume allows for pressure generation and control up to 200 MPa (30,000 psi) with minimal physical effort
• Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation
• Unique test port design eliminates the need for PTFE tape or wrenches. Adapters included for 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5
• Compatible with a wide range of liquids, including water. Vacuum fill kit included to fill the E-DWT with any compatible test medium
• AutoTest™, AutoRange, ready/not ready indicator, onboard data capture and storage, overpressure alarm, RS-232 remote interface and other advanced features to simplify testing, improve safety and prevent calibration errors and damage to equipment
• Optional foot switch accessory allows hands-free data collection when running AutoTests
• Rechargeable battery pack and transport case options for field operation

Key Features
• Eliminates the need for weights and piston-cylinder changes.
• Real-time pressure indication without need for corrections.
• Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
• Offers ± 0.02% of reading total one-year measurement uncertainty.
1AC II NonContact Voltage Tester
Fluke 1AC II Non-Contact Voltage Tester
• Be aware of voltage easily - the tip glows red and a beeper sounds when voltage is detected

• Continuous self-test so you always know it’s working

• Voltage detection range for wide application use - 90 V to 1000 V AC or 200 V to 1000 V AC

• Audible/Silent mode for added convenience
750P31 High Pressure Module 0700 Bar 2X Burst Rating
Fluke 750P31 High Pressure Module, 0-700 Bar, 2X Burst Rating
Fluke 750P31 Offers



Fluke 750P Series Pressure Modules are easy to use. To measure pressure, connect the pressure module to a pressure source or hand pump and then connect the pressure module cable to the calibrator. Apply pressure from the pressure source and it is displayed digitally on the calibrator. At the touch of a button, the pressure may be displayed in up to 11 different engineering units. When used with the 750 Series Documenting Process Calibrators, pressure readings can be date/time stamped and stored electronically for later retrieval. This saves time, eliminates errors, and supports F85compliance with quality standards and regulations.



Features

- Parameter/Range:0 to 10000 psi (0 to 700 bar)

- Burst Rating6:2x

- Hi Side Media2:316 SS

- Lo Side Media2:N/A

- Reference Uncertainty4:± 0.0175%

- Total Uncertainty 1-year (15-35°C):± 0.035%

- Total Uncertainty 1-year1:± 0.045%

- Total Uncertainty 6-month (15-35°C):± 0.03%

- Total Uncertainty 6-month1:± 0.04%