a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Measuring Tools

Fluke 369 True-rms Leakage Current Clamp Meter

Reduced downtime - find current leaks without shutting down equipment



The Fluke 369 FC true-rms leakage current clamp meter helps users detect, document, record, and compare leakage current readings over time to prevent unexpected downtime, and identify intermittent trips of GFCI and RCDs, all without the need to turn the equipment off.



The Fluke 369 FC has a very large 61 mm clamp for working with extra large conductors. The clamps are fully coated so that they can accurately capture very small leakage signals, and can minimize external electromagnetic interference.



Download
Products Lainnya
Fluke Calibration 1620A Precision ThermoHygrometer
Fluke Fluke Calibration 1620A Precision Thermo-Hygrometer
Product overview: Fluke Calibration 1620A Precision Thermo-Hygrometer
Accuracy
The standard-accuracy sensor (“S” model) reads temperature to ±0.25 °C over its calibrated range of 15 °C to 35 °C. Relative humidity readings are to ±2% RH from 20% RH to 70% RH.
All DewK sensors come with accredited certificates of calibration for both temperature and humidity, complete with data and NIST traceability.
Ethernet and wireless capability
With its built-in Ethernet RJ45 jack, multiple DewKs can be monitored from the same screen using Log Ware III client-server software. Ethernet also gives you the possibility for remote connectivity over the internet, so you can monitor critical conditions while you’re away.
Cables running along the floor can be a safety hazard, and cables hanging from the ceiling and walls are an eyesore. With the DewK, simply connect your computer through an RF modem up to 100 ft away, without the clutter of all the extra cables.
If you need a printout, send data to a printer through the RS-232 interface in real time.
Math and statistical functions
In addition to temperature and humidity, the DewK calculates dew point, heat index, and rates of change for both temperature and humidity. Min, max, and a variety of other statistics are also calculated and can be shown on-screen. Daily summary statistics, including min, max, and maximum rates of change are stored for the most recent sixty days.
Calibrated sensors
With inputs for two sensors, each measuring both temperature and relative humidity, one DewK can monitor two locations at the same time. Both sensors can be run via extension cables to remote locations up to 100 feet away, or one sensor can be directly mounted to the top of the DewK.
Each sensor is calibrated for both temperature and humidity by Fluke Calibration. The calibration constants assigned to the sensors reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably between different DewKs, and the recalibration of sensors doesn’t require an accompanying DewK.
Sensors may also be assigned a unique identifier (up to 16 characters) to facilitate record keeping by matching the sensor identifier with the collected data. Each DewK ships with one sensor, with additional sensors available directly from your local Fluke Calibration sales representative, or directly from Fluke Calibration. Spare sensors may also be purchased from Fluke Calibration as a kit, which includes a case for the sensor, a wall mounting bracket, and a 25-foot extension cable.
Memory
The DewK has enough on-board memory to store up to 400,000 date- and times stamped data points. That’s two years' worth of data for both measurements from two sensors if readings are taken every ten minutes!
Alarms and battery backup
Alarm settings can be set up quickly in the DewK based on temperature, the rate of change in temperature, RH, the rate of change in RH, and instrument fault conditions. Alarms can be both visual (flashing display) and audible (beeping). Likewise, alarm settings can be set up and events triggered in Log Ware III. The DewK is also equipped with a 0 to 12 volt alarm output that can trigger a process control system.
A backup battery shuts down the DewK’s display but maintains measurements for up to 16 hours in the event of a power failure.
Large, easy-to-read display
Want to view data from across the room? Want to view data from two temperature and two humidity inputs simultaneously? Want to view data graphically, statistically, or both? At the same time?! The DewK does everything you could want—or at least everything we could think of. Up to sixteen different display setups can be stored and recalled at the touch of a single button. And all 16 can be easily modified, so you get exactly what you want.

Key Features
• Highly accurate thermo hygrometer and humidity monitor.
• Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
• Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
• Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.
• Ttwo interchangeable calibrated sensors, a large memory capacity, and upgraded software.
Fluke FEV100 Electric Vehicle Charging Station EVSE Test Adapter
Fluke Fluke FEV100 Electric Vehicle Charging Station EVSE Test Adapter
Test the safety and performance of a type 1, level 1 or level 2 electric vehicle ac charging stations (EVSEs) with the Fluke FEV100. This test adapter simulates the presence of an electrical vehicle, allowing you to conduct tests in combination with appropriate test instruments such as a digital multimeter or oscilloscope. Use the FEV100 to verify an EVSE is working properly after install and during periodic maintenance, or troubleshoot an EVSE if it is not delivering the appropriate charge.
Electrical safety
EVSE charging cables may become damaged over the course of use, increasing electric shock risks to users. Stay protected from and check risk of electric shock with the GFCI trip test. This function verifies the breaker of the EVSE is connected by detecting ground faults. Additionally, the PE grounding protection pre-test verifies that there is no presence of dangerous voltage at the ground terminal.
Simplicity and convenience
Perform a variety of tests including ground fault checks, insulation of wires, measuring voltage and duty cycle to see max current available for charging all in one adapter that safely integrates with the Fluke portfolio of test and measurement tools. There is no need to bring an electric vehicle onsite for EVSE troubleshooting: the adapter acts as an electric vehicle when connected to an EVSE for easy performance and maintenance testing.
Recommended tools for use with the FEV100

Key features
• Check protective earth for correct wiring and functioning with the PE pre-test feature.
• Perform GFCI troubleshooting of EVSE and verify operation within safety standards.
• Test charging states of EVSE with CP state simulation.
• Verify charging voltage and maximum available current using a multimeter.
• SAE J1772 compliant to North American standards.
8200mm COOLANTPROOF IP 67 DIGITAL CALIPER
Kennedy 8"/200mm COOLANT-PROOF IP 67 DIGITAL CALIPER
Available in a range of sizes, this digital caliper is coolant, water and dust proof to IP67 level. It has a large LCD display, fast response speed, dual readout (mm/inch) and can be used for inside, outside, depth and step measuring. Also enables absolute and relative reading.



Extra batteries available - Order Code PAN9042505E 3V Lithium Metal cell
726 Precision Multifunction Calibrators
Fluke 726 Precision Multifunction Calibrators
Process calibration designed specifically for process industries



The Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals. It measures and sources almost all process parameters to calibrate almost anything. Use it to test sensors and valves, and to test and calibrate transmitters. The 726 interprets results without the help of a calculator and stores measurement data for later analysis.



Measurement capabilities



This precision multifunction calibrator measures volts, mA, pressure, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters. The 726 also sources and simulates volts, mA, thermocouples, RTDs, frequency to calibrate transmitters. Measures and/or sources pressure using when paired with any of the 50 Fluke 750P series Pressure Modules to test and calibrate pressure transmitters and other devices. The 726 can also:

- Source mA with simultaneous pressure measurement to conduct valve and I/P test

- Conduct enhanced flowmeter testing with frequency totalizer and frequency pulse train source mode



Designed for ease of use



The 726 has built-in features that make it easier to use in nearly any measurement situation. From its ability to store frequently used test setups, to programming custom RTD probe calibration constants for enhanced temperature measurement, or the integrated voltage input protection design that improves reliability, the 726 is built to perform. The use of two separate channels even allows you to measure, source, or view process signals simultaneously. The backlit display provides better visibility in low-light conditions, and the standard 3-year warranty provides extra confidence that the 726 will be there when you need it to be.



You can also use the 726 to:

- Capture the set, reset, and deadband of a pressure switch with the integrated switch test

- Calculate the transmitter error % to interpret calibration results without the use of a calculator

- Perform fast linearity tests with the auto-step and auto-ramp features

- Power a transmitter during test using 24 V loop supply and simultaneous mA measurement